Decoding the world of cybersecurity

VMware patches vCenter zero-day exploited since September

VMware has patched a critical vulnerability exploited since September 2026. Google’s investigation links attacks against vCenter management infrastructure to a suspected Chinese espionage group that obtained privileged access before the…

VMware patches vCenter zero-day exploited since September
Summary
  • CVE-2026-123890 allows unauthenticated attackers with network access to bypass VMware vCenter authentication.
  • Google and Mandiant documented exploitation by suspected Chinese espionage group ARMORY CASTLE in September.
  • Broadcom released fixes on 19 November, with no workaround identified for affected deployments.

Broadcom has released security updates for a critical VMware vCenter vulnerability that a suspected Chinese espionage group exploited more than two months before its public disclosure, exposing the central management systems used to administer enterprise virtualisation infrastructure.

The vulnerability, CVE-2026-123890, affects VMware Directory Service within vCenter Server and carries a CVSS severity score of 9.8 out of 10.

A remote attacker with network access to a vulnerable system can bypass authentication and obtain privileged access to the vCenter management environment.

Broadcom published security advisory VMSA-2026-0009 on 19 November 2026, releasing fixes for affected products. The advisory was updated the following day to clarify additional affected software versions.

Investigators from Mandiant and Google Threat Intelligence Group (GTIG) subsequently disclosed evidence that the vulnerability had been exploited in early September by a suspected Chinese espionage group tracked as ARMORY CASTLE.

The researchers identified the activity during an investigation into intrusions involving compromised remote support infrastructure and subsequent movement into internal networks.

Attackers gained privileged management access

VMware vCenter provides centralised administration for vSphere environments, allowing organisations to configure virtual machines, manage hosts, and monitor the infrastructure supporting business applications.

Its position within the architecture gives it extensive administrative capabilities over the systems it manages.

Consequently, compromise of vCenter can expose more than an individual server. Attackers who obtain sufficiently privileged access may be able to modify virtualisation settings, access sensitive management information, or interfere with workloads that depend on the platform.

Google’s investigation established that ARMORY CASTLE used a purpose-built exploitation utility named BONESAW to take advantage of the authentication weakness.

The flaw affects the authentication mechanism used by the VMware Directory Service. Successful exploitation allowed the attackers to establish a privileged administrator session without possessing the expected authentication credentials.

During the observed campaign, the attackers used the resulting access to obtain internal directory information and create additional privileged access within the virtualisation management environment.

The researchers also identified malware and utilities supporting reconnaissance, credential theft, persistence, and movement between compromised systems.

These findings establish that exploitation was not limited to a theoretical authentication bypass. In the investigated environment, the attackers used the vulnerability as part of a broader intrusion that reached critical management infrastructure.

Google assesses ARMORY CASTLE as a suspected Chinese state-linked espionage actor. The attribution is based on threat intelligence and observed activity rather than a public admission by the suspected operators.

The company’s investigation also documents the use of a separate zero-day vulnerability affecting BeyondTrust Remote Support, which had provided an earlier route into the targeted environment.

Separate vulnerabilities enabled successive access

The campaign illustrates how vulnerabilities in different infrastructure products can be combined during a sustained intrusion.

Following the compromise of remote support equipment, the attackers moved into internal Linux appliances and established additional capabilities for maintaining access and examining the surrounding network.

The subsequent exploitation of vCenter provided a route into systems responsible for administering virtual machines and their underlying hosts.

That sequence placed the virtualisation environment at risk even though the original entry point was a different technology platform.

Many organisations operate remote administration systems and virtualisation infrastructure as distinct services, with separate maintenance procedures and administrative teams.

However, both may carry privileges that extend across substantial parts of the enterprise environment. Compromise of one can create opportunities to investigate and attack the other when network access and security controls permit.

The investigation also highlights difficulties associated with monitoring infrastructure appliances. Such systems may not support the same endpoint security tooling routinely installed on employee computers or application servers.

Google reported that some compromised internal Linux appliances lacked endpoint detection and response software, allowing the attackers to operate in areas with reduced security visibility.

Broadcom releases fixes across affected products

Broadcom’s November advisory covers five vulnerabilities affecting VMware vCenter, SDDC Manager, and VMware Tools.

The most severe is CVE-2026-123890, the vCenter authentication bypass. The other vulnerabilities involve SQL injection, command injection, local privilege escalation, and a security token signature bypass under specific conditions.

The confirmed September exploitation concerns the vCenter authentication weakness. The available evidence does not establish that all five vulnerabilities were used during the same campaign.

For vCenter, Broadcom identifies 8.0 Update 3m, 9.0.2.0200, and 9.1.1.0200 as fixed releases for the corresponding software branches.

VMware Cloud Foundation and related products have additional version-specific requirements, while organisations operating vCenter 7.0 under extended support are directed to contact Broadcom.

The vendor lists no workaround for CVE-2026-123890. Installing the relevant security update is therefore the corrective measure specified in its advisory.

However, a successful update does not establish whether an installation had already been compromised before the vulnerability became public.

Where earlier exposure is suspected, security assessments may need to consider privileged account changes, unexpected management activity, and the integrity of systems administered through vCenter.

The incident is particularly relevant to organisations operating extensive virtualisation estates, where a single management platform may control workloads supporting finance, manufacturing, healthcare, government, or other important services.

Compromise of that administrative layer can create consequences for identity security, infrastructure integrity, operational continuity, and recovery planning.

Broadcom’s advisory provides the affected product versions and corrective releases, while Google’s investigation documents the exploitation and associated intrusion activity.

The public research confirms use of CVE-2026-123890 in September but does not establish the total number of affected organisations or identify every victim of the campaign.

×